Flow Cytometer Analyzer - Moxi GO II™

The Moxi GO II™ from Orflo Technologies (a subsidiary of Gemini BioProducts, LLC) is a benchtop flow cytometer analyzer that utilizes a disposable thin-film cassette and a combination of a 488 nm laser, two photomultiplier tubes (525/45 nm filter with either a 561nm LP filter or 646nm/LP filter, user-swappable), Coulter Principle-based cell measurements, and on-board software to provide easy-to- run applications and data analysis. 

Moxi GO II

The instrument relies on disposable cassettes for sample handling, which alleviates the need for flow cell cleaning and fluidics maintenance. The instrument is small enough to be portable between the lab bench and the hood. A touchscreen interface and simplified GUI allows for ease of operation without extensive training.

制造商:  Orflow技术                               
模式#:  MXG 102
生产年份:
收购:
地点: 鲁德曼大厅279

规范

系统性能

  • Detection parameters:  5 (2-color fluorescence, cell count, cell size, forward extinction)
  • Excitation Laser Wavelength:  488 nm
  • pmt数量:2
  • Optical Detection Range:  PMT1: 525/45 nm (e.g FITC, GFP, Alexa 488); PMT2: User-swappable, either 561 nm LP (e.g PE) or 646nm/LP (PI, avoids need for compensation)
  • Particle count/size detection:  Impedimetric (Coulter Principle)
  • Display:  480 x 800 pixels; color touchscreen
  • Resolution:  1000 histogram bins
  • 数据存储:4gb
  • Connectivity:  USB-on-the-go
  • Data Output:  On-system data analysis with exceptional export of BMP files and FCS compatible raw data files (FCS 3.1, compatible with FlowJo and other offline software analysis platforms)

盒性能

  • Compatible sample types:  细胞贴壁 & Non-adherent primary cells or cell lines) and Beads
  • Number of tests per cassette:  2
  • Sample volume required:  60 μl最低
  • Particle/cell size range
    • S+型卡带: 3-27μm diameter (14 – 10,306 fL volume)
    • MF-M cassette: 4-35μm diameter (14 – 22,449 fL volume)
  • 浓度范围
    • S+型卡带
      计数:1 × 104 – 1.75 x 106细胞/毫升
      Optimal fluorescence:  < 5 x 105 细胞/毫升
    • S+型卡带
      计数:1 × 104 – 1.75 x 106细胞/毫升
      Optimal fluorescence:  < 5 x 105 细胞/毫升
  • 测量时间:  ~ 5-10秒

原理的科学家:  唐Wojchowski

 

View UIC Knowledge Base

The Knowledge Base contains forms, instruction and training material, 分钟, 政策, tools and other resources to support your research efforts by topic area.


联系信息

唐Wojchowski
鲁德曼大厅279
达勒姆,新罕布什尔州03824

 

利率

中率:
$45.00 /小时协助

$5.00 /小时无助的

Non UNH academic Rate:
协助100美元/小时

无助的50美元/小时

业率:
协助100美元/小时

无助的50美元/小时